Skip to main content

Get Specific Site WAN Interface (v2.6)

GET 

/v2.6/api/tenants/:tenant_id/sites/:site_id/waninterfaces/:wan_interface_id

Get a specific site wan interface.

Request

Path Parameters

    tenant_id stringrequired

    The tenant ID.

    site_id stringrequired

    ID of the site. More details on the site can be retrieved by querying the sites API.

    wan_interface_id stringrequired

    ID of the WAN interface.

Responses

Successful Operation

Schema
    bfd_mode stringrequired

    Possible values: [aggressive, non_aggressive]

    Allowed values: aggressive - For fast failure detection of links. This mode is the default mode and is recommended by Prisma SD-WAN. non_aggressive - when you want to reduce the amount of probe traffic, or for links that are subjected to high loss or poor quality.

    bw_config_mode stringrequired

    Possible values: [auto, manual, manual_bwm_disabled]

    The bandwidth config mode.

    bwc_enabled boolean

    Bwc Enabled

    cost integer

    Cost value for the site WAN interface should be within range 0-1024.

    description

    The description of the WAN interface config (size max = 256).

    id string

    The ID.

    label_id stringrequired

    The WAN interface label or Circuit label ID. This can be retrieved using the waninterfacelabels API.

    link_bw_down double

    The circuit downstream capacity in MB.

    link_bw_up double

    The circuit upstream capacity in MB.

    lqm_config LQMConfig

    The link quality monitoring parameters.

    hub_site_ids string[]

    List of DC Site IDs.

    inter_packet_gap int32

    Allowed values: 50-300 milliseconds.

    statistic string

    Possible values: [min, max, avg]

    WAN interface LQM config statistics.

    lqm_enabled boolean

    The link quality monitoring parameters.

    name string

    The name of the WAN interface config (size max = 128).

    network_id stringrequired

    The network ID.

    tags string[]

    An information field that can be added to identify the application. Maximum 10 Unique tags of length 1024 each are allowed.

    type string

    Possible values: [PUBLIC_WAN, PRIVATE_WAN]

    Type of WAN.

    use_for_application_reachability_probes boolean

    Indicates if the use for application reachability probe is selected.

    use_for_controller_connections boolean

    Indicates if the use for controller connections is selected.

    vpnlink_configuration VPNLinkConfiguration

    The configuration of the VPN link.

    keep_alive_failure_count integerrequired

    The VPN keep alive failure count (must be between 3 and 30).

    keep_alive_interval integerrequired

    The VPN keep alive timeout interval (must be between 100ms-1740,000ms).

Loading...